Cal unit deployment procedure

- Enable telescope Stow Pins

- Put telescope on HBS

- Laptop and climbing tools are stored on 3L, on ARGOS shelves

- Attach laptop to power cord and gray ethernet cable

- Laptop login: argos, pwd: argos2009

- Climb and remove optics cap

- On laptop click first "set default parameters", then "reset", then "move to working position"

- Switch off high floods lights (1st and 2nd botton on "lighting" tab on telescope control gui)

- Deploy dichroic

Switching on light

- login into LALAS: IP 192.168.26.149, pwd: argos123

- ON-AXIS SOURCE REFLECTION: argos_dx_cal_white_light_source_gui

- ON-AXIS SOURCE TRANSMISSION THROUGH HOLOGRAM: argos_sx_cal_white_light_source_gui

- OFF-AXIS SOURCES: argos_dx_las_or_lgsw_swing_arm_diode_source_gui
Topic revision: r2 - 12 May 2014, MarcoBonaglia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding AOWiki? Send feedback