8:00: start of activity, telescope at horizon, WG and DP go up to install the camera to measure the LAS pupil mirror to LM1 coordinates orientation.
11:00: telescope back to zenith,
CalUnit in, dichroic in, hexapod adjusted to fit sources into LGSW
DARK: 20141105_172349
Pupil |
PI X |
PI Y |
Blue |
-0.45 |
-1.14 |
Yellow |
-3.38 |
2.15 |
Red |
-0.96 |
-1.75 |
HEXAPOD: X = -3.02, Y = -6.27, Z = 4.48, Rx = -239, Ry = 32
We center the
FLAO board on the rotator using stages: X = -75, Y = -49, Z = 50
12:00: we are ready to close the loop on ARGOS, but we find a bug in the LGSW controller -- SOLVED
Alfio tells us how to solve the problem with the offload: the hexapod coordinates have to be inserted into the big PSFGUI where all the corrections must be removed and the lookup tables disabled (see
HowToEnableHexapodOffload).
NOTE: at 12:30 we find a bug in the gain procedure, all the modes share the same gain value equal to the HO gain.... We will just write the HO gain in this log untill the bug has been solved...
ARGOS TN |
FLAO TN |
Notes |
Res. |
20141105_190535 |
20141105_191018 |
ARGOS CL g =0.2, disturb =1.2" |
86 |
20141105_191124 |
20141105_19452 |
" |
93 |
We set gain to 0.6 and we RIP the shell...
We have another problem with the RR mode that was not enabled and LB finally succeded in crashing the primary...
Gain bug fixed!
We try to move the blue pupil motor while the loop is closed without disturbance: the shell fails at 2/10 of subaperture shift.
ARGOS TN |
FLAO TN |
Notes |
Res. |
20141105_195158 |
20141105_195103 |
OL |
597 |
20141105_195304 |
|
" |
530 |
20141105_195646 |
20141105_195529 |
CL, g 10 modes = 0.5, gHO = 0.4 |
103 |
20141105_195718 |
|
" |
102 |
20141105_200024 |
|
gTT=0, Jitter OL, shell crash |
145 |
20141105_200652 |
|
gTT=0, Jitter CL, OK |
85 |
20141105_200740 |
20141105_200616 |
BAD: shell safe skip |
119 |
20141105_201544 |
20141105_201545 |
g=(0.5,0.4) |
99 |
20141105_201715 |
|
g=(0.5,0.4) |
102 |
20141105_202052 |
20141105_201928 |
g=(0.5,0.4) |
104 |
20141105_202656 |
20141105_202552 |
g=(0.5,0.4), FLAO TN is BAD: Alfio moved stages while acquiring |
97 |
20141105_204541 |
20141105_204411 |
g=(0.5,0.4) |
96 |
13:20: Gilles generates a new REC from IM 20141104_195926 filtering out the TT modes from the others. Doing this we find a bug in the procedure that was filtering out TT even from TT modes themself -- SOLVED.
REC = 150modes_ryb_300Hz_TTremoved.fits
13:45: we load the new reconstructor and close again the loop on ARGOS.
ARGOS TN |
FLAO TN |
Notes |
Res |
20141105_205114 |
20141105_204950 |
Filtered rec, g=(0.5,0.4) |
91 |
20141105_205157 |
|
" |
91 |
20141105_205306 |
20141105_205231 |
BAD: we opened the loop but the hexapod offload was not disabled |
611 |
There is a bug in the nice interface: when the gain is set to 0 the hexapod offload is not disabled -- SOLVED by Aflio!
We center again the LGS with the Hexapod, new PI static values:
We try to open again the TT putting gain=0 and to close the Jitter loop:
ARGOS TN |
FLAO TN |
Notes |
Res |
20141105_211557 |
20141105_211435 |
Jitter CL, all other OL |
600 |
20141105_211707 |
|
complete OL, disturb = 1.2" |
600 |
20141105_211900 |
20141105_211737 |
Jitter CL + 10 modes on ARGOS |
400 |
14:30: we load disturb equivalent to
1.6", wind= 15m/s, 1kHz oversampling
ARGOS TN |
FLAO TN |
Notes |
Res |
20141105_213517 |
20141105_213407 |
OL |
848 |
20141105_213606 |
|
OL |
848 |
20141105_213735 |
20141105_213610 |
CL, g=[0.5, 0.3] |
97 |
20141105_213908 |
|
" |
97 |
20141105_214031 |
|
" |
99 |
20141105_214139 |
|
" |
97 |
20141105_214251 |
|
" |
100 |
We load disturb equivalent to
0.8", wind= 15m/s, 1kHz oversampling
ARGOS TN |
FLAO TN |
Notes |
Res |
20141105_214523 |
20141105_214359 |
OL |
449 |
20141105_214607 |
|
" |
448 |
20141105_214634 |
|
" |
448 |
20141105_214737 |
20141105_214612 |
CL, g= [0.5, 0.3] |
90 |
20141105_214817 |
|
" |
90 |
20141105_214844 |
20141105_214727 |
" |
90 |
20141105_214909 |
|
" |
90 |
20141105_214935 |
20141105_214825 |
" |
91 |
We try now to reduce flux, until now we had 4000 ADU/subap, we go now to
2000 ADU/subap and we set a disturb equivalent to
1.2"
ARGOS TN |
FLAO TN |
Notes |
Res |
20141105_215915 |
20141105_215752 |
2000 ADU/subap, CL g=[0.5, 0.3] |
120 |
20141105_215942 |
|
" |
119 |
20141105_220006 |
|
" |
118 |
We try to reduce the flux at
1000 ADU/subap and to close with gain [0.5, 0.3] but the loop diverges...
We acquire another
DARK: 20141106_220741
Pupil loop seems very unstable, we try to disable it and the loop is more or less stable even with 1000 ADU/subap:
ARGOS TN |
FLAO TN |
Notes |
Res |
20141105_221250 |
20141105_221159 |
1000 ADU/subap, CL g=[0.5, 0.3] |
166 |
20141105_221329 |
|
" |
166 |