9:00: we startup both systems but we first try to close a loop w/ PYR on the
DX system.
We try to reoptimize the pupil motors positions while in CL:
Then we load
0.8" disturb:
Then we move to
SX system
No disturb:
The system oscillation is triggered by the top right edge of the pupil.
We try w/ LGSW only:
The astigmatism oscillates more w/ PYR than LGSW only...
We try a loop w/ PYR Bin4 only:
TN |
AO Gain |
AO CL |
TT Res. WF [nm rms] |
HO Res. WF [nm rms] |
AO rec |
DIMM ["] |
JCL |
PCL |
Notes |
20170429_215804 |
0.5,0.55,0.3 |
T |
190.92 |
239.876 |
20160313_063600 |
-1 |
F |
F |
|
20170429_220029 |
0.5,0.4,0.3 |
T |
120.582 |
61.58 |
20160313_063600 |
-1 |
T |
F |
|
20170429_220055 |
0.5,0.4,0.4 |
T |
117.709 |
62.3783 |
20160313_063600 |
-1 |
T |
F |
|
20170429_220126 |
0.5,0.45,0.45 |
T |
145.657 |
122.985 |
20160313_063600 |
-1 |
T |
F |
|
20170429_220154 |
0.5,0.5,0.5 |
T |
178.542 |
191.503 |
20160313_063600 |
-1 |
T |
F |
|
20170429_220219 |
0.5,0.6,0.6 |
T |
230.557 |
275.299 |
20160313_063600 |
-1 |
T |
F |
|
20170429_220248 |
0.5,0.7,0.7 |
T |
232.779 |
365.725 |
20160313_063600 |
-1 |
T |
F |
|
20170429_220322 |
0.5,0.8,0.8 |
T |
228.054 |
409.679 |
20160313_063600 |
-1 |
T |
F |
|
With PYR the whole pupil is oscillating, not just an edge...
We move back to
DX system:
TN |
AO Gain |
AO CL |
TT Res. WF [nm rms] |
HO Res. WF [nm rms] |
AO rec |
DIMM ["] |
JCL |
PCL |
Notes |
20170429_221958 |
0.6,0.4,0.3 |
T |
55.3739 |
51.8303 |
20161205_222600 |
-1 |
T |
F |
|
20170429_222020 |
0.6,0.4,0.3 |
T |
58.5788 |
51.6601 |
20161205_222600 |
-1 |
T |
F |
|
20170429_222100 |
0.6,0.5,0.4 |
T |
58.3075 |
58.139 |
20161205_222600 |
-1 |
T |
F |
|
20170429_222222 |
0.6,0.6,0.55 |
T |
91.3458 |
410.791 |
20161205_222600 |
-1 |
T |
F |
|
20170429_222249 |
0.6,0.6,0.55 |
T |
91.032 |
366.776 |
20161205_222600 |
-1 |
T |
F |
|
20170429_222327 |
0.6,0.6,0.6 |
T |
63.8895 |
341.071 |
20161205_222600 |
-1 |
T |
F |
|
Also here the whole pupil oscillates...
Since the SX oscillation is always triggered by the top right pupil we check if it could be a problem due to mis-calibration... We acquire new IMs with 0.05, 0.10 and 0.20 modal amplitudes. Just the latter case is decreasing the blue pupil illumination when performing push-pull (saturation?).
- COMBO REC TCoG48 only: 20170429_235900 has been created w/ 0.05 modal amplitude

- COMBO REC TCoG48 only: 20170430_001401 has been created w/ 0.20 modal amplitude
TN |
AO Gain |
AO CL |
TT Res. WF [nm rms] |
HO Res. WF [nm rms] |
AO rec |
DIMM ["] |
JCL |
PCL |
Notes |
20170430_000452 |
0.5,0.5,0.5 |
T |
220.869 |
43.6118 |
20170429_235900 |
-1 |
F |
F |
|
20170430_000601 |
0.5,0.6,0.6 |
T |
213.004 |
51.2372 |
20170429_235900 |
-1 |
F |
F |
|
20170430_000630 |
0.5,0.7,0.7 |
T |
208.839 |
117.197 |
20170429_235900 |
-1 |
F |
F |
|
20170430_000859 |
0.5,0.7,0.7 |
T |
287.695 |
235.045 |
20170429_235901 |
-1 |
F |
F |
|
20170430_000949 |
0.5,0.5,0.5 |
T |
219.931 |
51.4049 |
20170429_235901 |
-1 |
F |
F |
|
20170430_001110 |
0.5,0.4,0.3 |
T |
217.348 |
38.4317 |
20170429_235901 |
-1 |
F |
F |
|
20170430_001626 |
0.5,0.4,0.3 |
T |
237.232 |
50.797 |
20170430_001401 |
-1 |
F |
F |
|
20170430_001658 |
0.5,0.5,0.5 |
T |
226.294 |
62.7028 |
20170430_001401 |
-1 |
F |
F |
|
20170430_001728 |
0.5,0.7,0.7 |
T |
219.561 |
178.746 |
20170430_001401 |
-1 |
F |
F |
|

Also in these cases the oscillation is triggered by the top right edge of the pupil...