*** IMPORTANT: This configuration has been removed. Final solution uses a fiber switch. It is left here for reference only. (GR/2017-02-10) See HowToUseTheFiberSwitch instead***

*

The ARGOS fiber splitter is needed to double the output channels of FLAO fastlink and direct the first output directly to the AdSec, while the second FLAO output is direct to the ARGOS BCU.

FiberSplitterSx.jpgFiberSplitterDx.jpg

In addition to the connections highlighted in the above drawings the ARGOS BCU is directly linekd to the AdSec:
  • ARGOS SX-WFS (BCU output) LIU-0602-7-4 is connected to AO-SX Fastlink ARGOS LIU-0605-2-3
  • ARGOS DX-WFS (BCU output) LIU-0602-8-4 is connected to AO-SX Fastlink ARGOS LIU-0605-5-3

Detailed documentation of the Upper Left and Lower Treehouses (ULTH and LLTH/LRTH) fiber connections: -- MarcoBonaglia - 19 May 2016

This topic: ARGOSPublic > WebHome > ListOfHowTo > HowToInstallARGOSFiberSplitter
Topic revision: 20 Oct 2017, LorenzoBusoni
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding AOWiki? Send feedback