List of devices of this kind 
  Documentation 
  
  
  
  Installation and maintenance 
  Communication with MoCon using HTerm 
    Julian Ziegleder uses HTerm (but you can also use hyperterminal):
 
-  Connect the serial cable (9600 baud, 8bits, 1 stop, no parity)
-  set Newline at LF
-  Input control-> send on enter CR
  How to set IP 
 
-  Get IP address 1 31 0. It was set to 172.20.239.61
-  Set IP address to the desired IP (e.g. 192.168.18.4): 1 30 0 192 168 18 4
-  Get IP mask and gateway with 1 33 0 and 1 35 0. They were set to 255.255.255.255
-  New values are valid after a reset 1 8 0
-  When serial connection is no more needed it must be disabled using . See User Guide p. 21 (Communication mode and card address) and ask JZ.
  Communication with MoCon using OAA IDL library 
This can be useful for troubleshooting and to discriminate between SW and HW issues.
The library is installed in 
WorkStation1 in ~/idl/usr_lib/mocon that is already in the IDL path. 
Identify the cardno (=1 in the Lgsw case) and the motorno (between 1 and 8), depending on the port used to connect the device to the 
MoCon. 
See for example 
AdaptorBox for a list about how the motors and the dark wheel of 
LgswUnit are connected.
Start IDL and see the example below where cardno=1 and motorno=1.
Typically you want to use genericCmd(cardno, code, motorno, param) and refer to the 
MoCon Programmers Guide
IDL> mocon=getmocon('192.168.29.41')                     
% Compiled module: GETMOCON.
% Compiled module: MOCON__DEFINE.
% Compiled module: MOCON_MSGQUEUE__DEFINE.
1 6 0 4 COS_XC161 V2.19, Nov 23 2012
IDL> mocon->TCPLogin, 1           
IDL> mocon->TCPPassword, 1
IDL> mocon->SetFirmwareSettings, 1, INFO_MODUS=0           
IDL> mocon->TCPReserveModule, 1, 8                
IDL> mocon->info, 1, 8
--- Amplifier Card 1 Info's ---
Classification: Stepper
Identification: 0x1
Card Name: SMD8
Version: 2.0
Manufacturer date: 16.09.2010
Serial No.: 021
Amplifier offset: 0
--- Amplifier Info's ---
Classification: Stepper
Identification: 0x2
Amplifier name: IM481Hplus
Motor power supply: OK
Amplifier fuse: OK
Thermal flag: no support
Short current flag: no support
PWMa/Pulse inverse: No
PWMb inverse: No
PWMc/AtRest inverse: No
Sign/Dir inverse: No
Break/PowerOff inv.: Yes
Auto PowerOff inv.: No
IDL> print, mocon->position(1, 8)
           0
IDL> ret= mocon->genericCmd(1, 163, 8, '') & help, ret[0]
** Structure <2309678>, 9 tags, length=88, data length=88, refs=2:
   LINE            STRING    '1 163 8 2 0'
   CARD            INT              1
   CODE            INT            163
   MODULE          INT              8
   MSG_ID          INT              2
   DATA            STRING    '0'
   INFO            STRING    ''
   EVENT           STRING    ''
   ERROR           STRING    ''
  How to adjust current 
Current for each channel of the card has to be adjusted.
Please check first the current of each channel before you connect it to the motor.
Each channel has a measuring point and a potentiometer. Please set each channel to 0,286V if the motor is not running. 
If the motor is running you should measure 0,340V -> 340mA.
On 23 March 2012 I did it on the old card SMD8 S/N17. On 11 October 2012 It is repeated on SMD8 S/N21
  
  Reference 
This topic is referred in:
AvtCamera, 
CableAdaptorBoxMocon, 
CableAdaptorBoxMocon1, 
CableAdaptorBoxMocon2, 
CableAdaptorBoxMocon3, 
CableAdaptorBoxMocon4, 
CableAdaptorBoxMocon5, 
CableAdaptorBoxMocon6, 
CableAdaptorBoxMocon7, 
DarkWheel, 
DarkWheelMotor, 
DayTime20150821, 
MoconBinder, 
MoconBoard, 
MoconSMD8Board21, 
MoconWFSDX, 
MoconWFSSX, 
StepperMotorAdaptorBox, 
ThingsThatIDontUnderstand0007
  Topic label 
   |  |  | 