Who | When |
---|---|
J. Ziegleder | |
S. Rabien | |
W. Raab | |
G. Orban | |
M. Deysenroth | |
H. Gemperlein |
Setup was: we used the Arcetri alignment tools: a rail attached to the reference points on the table and the angle piece to define the center. We attached a sheet metal to this location and Matthias has printed us a target. The target center is therefore on the center of the wfs-as -aligned. it shows a circle with 159.xx mm radius. Accuracy of the printed target has been determined to be -0.5mm. 120° lines are aligned on the target. dxf file of the target can be delivered. Telescope has been put into Luci@argos position. which is: X: -5.0 Y: -5.45 Z:4.3 Rx-317.00 Ry-190 Rz:0 This results into image in focal position of wfs : S_IMG_9071 we then moved the hexapod in tip-tilt. resuklting into: X:-5.0 Y:-5.45 Z:4.3 Rx:-269 Ry:-148 Rz: 0 This results into frame 9076 From that on we have moved the target in 30mm steps away from the focus. according picture id and distance is:
I | Attachment | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|
![]() |
140211_report_(1).pptx | manage | 2 MB | 16 Sep 2014 - 14:37 | MarcoBonaglia | |
![]() |
ARGOS_dichroic_installation.pdf | manage | 951 K | 18 Sep 2014 - 12:59 | MarcoBonaglia | |
![]() |
Alignment_report.pdf | manage | 992 K | 16 Sep 2014 - 13:41 | MarcoBonaglia | |
![]() |
CalUnit_measurements.docx | manage | 525 K | 22 Sep 2014 - 12:30 | MarcoBonaglia | |
![]() |
ImageDistances.xlsx | manage | 11 K | 16 Oct 2014 - 12:30 | LorenzoBusoni | z-position of target, hexapod configuration, spot mismatch |
![]() |
Instructions_to_replicate_the_Hexapod_position.docx | manage | 312 K | 16 Sep 2014 - 14:38 | MarcoBonaglia |