System hardware The ArgosSystemSx is composed of: * the LgswSystemSx (WFS system) * the LasSystemSx (Laser system) * the LanSystemSx (Launch system) *...
Rationale We what to know the geometry between the ASM actuators indexes and the LGSW subapertures. This information have been used to build a syntetic IM between...
Is a goal of this topic Having a trace of every single occurred (or possibly occurred) bugs/failure in the hardware and/or software that is not fully understood ...
Summary of AO loop calibrations for the ArgosSystemDx Table below resumes the latest combined reconstructors built and tested in daytime: Combination Tag Suba...
Tricks for calibration on sky * Loop Closed on a bright NGS star with FLAO only 36 modes to keep proper collimation * VibrationCompensation ON * Optimise...
Full ARGOS Start up procedure This procedure describes how to start up ARGOS from scratch. After summer shutdown or a longer periode of non use the system might h...
Howto Acquire Frames With Patrol Camera At Full Speed Data acquired using tools in: argos@sx lgsw x64 $ pwd /home/argos/Downloads/AVTCam/AVT GigE SDK/bin pc/x64 ...
The following instructions apply if you are connecting from outside the telescope network. If you are at the telescope just follow HowToLogInAndConnectToVNC Logi...
There are 2 ways to perform a "coma free" pointing offset moving the AdSec hexapod: 1. using the TCS GUI 1. using the ARGOS terminal How to perform a point...
Rationale When working in day time with the CalUnitSystem the TCS must be informed. If this is not done the TCS offloads the static offsets of the ASM on the prim...
How to Perform ARGOS AO Loop In Night Time This HowTo describs what to do to set up the ARGOS system for night time observation. The procedure should start with h...
There are 2 ways to remove coma by moving the AdSec hexapod: 1 using TCS GUI 1 using the ARGOS terminal How to remove coma using the TCS GUI i. Login on...
How to setup the ARGOS system to measure LUCI pointing offsets The principle is to measure the LUCI pointing shift during a full rotator rotation while in closed ...
How to shutdown and power off ARGOS properly At the end of a night or at the end of a day work shutdown ARGOS by: * Press button "Shutdown" * Daytime work ...
Rationale In each WFS the 3 laser beams follow indipendent path (or "channels") up to the detector. This means that several devices inside the LgswUnit are instal...
Max Planck Institut fur Astronomie Wolfgang, Jose and Martin: refer to them for any software related question about LGSW and computer configuration and mainteinan...
Summary of AO loop calibrations for the ArgosSystemSx Table below resumes the latest combined reconstructors built and tested in daytime, this table represents th...
Look in HowToGenerateSinusoidalDisturbance to generate new Sinusoidal Disturbance SX KL_v18 sinusoidal disturbance ID modes amplitude nm Loop Freq Hz ...
Repository of technical notes * 100: Test of Prosilica/AVT GC1350 camera candidate as WFS patrol camera: .pdf, .doc * 101: PI S334.1SL test with Microgate H...
IMPORTANT NOTE: Do not modify this template topic unless you know what you are doing. If you want to create a new topic using this template use "Create New Topic...
Tomelleri srl is the company that produced most of mechanical parts of the LgswUnit, the LgswTable and the LgswDichroicSystem Contacts Web: www.tomelleri.com Raf...
When Symptom What to do Notes Cold start PowerOn fails, several devices are still unreachable (e.g. the LGSW rack is off). The Remote Power Switch (in l...