Backlinks to WorkStation in all Webs (Search ARGOSPublic Web only)

Results from ARGOSPublic web retrieved at 16:40 (GMT)

ArgosSystemDx
System hardware The ArgosSystemDx is composed of: * the LgswSystemDx * the LasSystemDx * the LanSystemDx * the CalUnitSystemDx * the TipTiltSystemD...
ArgosSystemSx
System hardware The ArgosSystemSx is composed of: * the LgswSystemSx (WFS system) * the LasSystemSx (Laser system) * the LanSystemSx (Launch system) *...
DiaryRun1
Who When M. Bonaglia 20140309 20140324 L. Busoni 20140309 20140324 T. Mazzoni 20140309 20140324 M. Kulas 20140310 20140324 H. Gemperle...
HowToBuildFlaoAndTrueSensRecsForArgos
Procedure If there are new Flao Recs this procedure will guide you in build the Rec for ARGOS based on the new FLAO Recs. i. Copy the new Recs from FLAO workstati...
HowToConnectToARGOSWorkstationAtLBT
The following instructions apply if you are connecting from outside the telescope network. If you are at the telescope just follow HowToLogInAndConnectToVNC Logi...
HowToDeployDichroic
How to deploy dichroic from ARGOS control software 1. See FullARGOSStartUpProcedure for prerequisites: chiller, main power, login into workstation 1. Start ...
HowToInstallNewReconstructorInArgosSW
First Step, table Update After a calibration you have to update the argos configuration table. In "argos_trunk/site/lbt/common/insroot/etc/argos_SIDE_foreman_con...
HowToLogInAndConnectToVNC
The following instructions apply if you want to run ARGOS from the obs machines in the LBT control room. If you are not at the telescope and want to run ARGOS rem...
HowToPowerUpLAN
This procedure brings up the LAN system until the launch system is ready for on sky laser propagation i. See FullARGOSStartUpProcedure for prerequisites: chil...
HowToPowerUpLAS
This procedure brings up the LAS system until lasers are ready to be propagated on sky i. See FullARGOSStartUpProcedure for prerequisites: chiller, main power,...
HowToPowerUpLGSW
This procedure brings up the LGSW system until the WFS is ready for on sky operation i. See FullARGOSStartUpProcedure for prerequisites: chiller, main power, l...
HowToUpdateTheArgosInstrumentSoftwareOnTheWorkstations
How To Update The ARGOS Instrument Software During Commissioning It is essential that the engineers know exactly which software modules run during the commissioni...
LabGUI
LabGUI This is the main engineering GUI that allows to control the full LgswSystem hardware. #StartLabGUI How to start the LabGUI i. Login on the workstation:...
LgswSystem
Description The term "LGSW System" refer to all the HW and SW related to the ARGOS laser guide star wavefront sensor on a single LBT eye. An LGSW system is compos...
MonitServiceManager
How to start i. Connect to the workstation i. Start argos_monit by executing the program for your workstation: host start up command dx lalas ar...
UsefulLoginInfo
Login credentials user host pwd hint argos argos dx easy one with numbers argos argos sx easy one with numbers argos dx lalas easy o...
VirtualBox
Both LGSW workstations WorkStation1, WorkStation2 have a Windows XP OS running on Oracle VM virtualbox. On Windows XP the following software is installed: * Mi...
WebHome
Welcome to the ARGOS Laser Guide Star twiki pages This twiki collects all the informations related to the 2 ARGOS laser guide star systems. It is written for the ...
WorkStation1
Identification Dell R520 Setup as DX LGSW. On the rear side close to the 2 power supplies there is a label CSC2H5J (27834711895). This is the service tag. On the ...
WorkStation2
Identification DELL R520 Setup as SX LGSW On the rear side close to the 2 power supplies there is a label H6W5ZX1. This is the service tag. The Express Service Ta...
WorkStation3
Identification Dell R510 Setup as dx lalas. On the rear side close to the 2 power supplies there is a label with the service tag: ST38XJB5B and the Express Servic...
WorkStation4
Identification Dell R510 Setup as sx lalas On the rear side close to the 2 power supplies there is a label with the service tag: ST48XJB5J and Express Serice Tag:...
WorkStation5
This is a spare server that is intented to stay in Arcetri for SW development and data analysis. Identification On the rear side close to the 2 power supplies t...
WorkStation6
This is a spare server currently located in Heidelberg (Faraday). Currently, the workstation is used for testing the software in simulation. Identification DELL ...
WorkStation7
Currently, the workstation is located in Heidelberg (Faraday) and used as backup system. Identification * Dell R520 * On the front side there is a plastic ...
WorkStation8
Currently, the workstation is located in Heidelberg (Faraday) and used for testing the software in simulation. Identification * Dell R520 * On the front si...
Number of topics: 26

No backlinks in public webs
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding AOWiki? Send feedback