DX LGSW setup 9:00 a.m.: we start up the LGSW. There is a problem with the state machine: in the powered off state the Thors are off and when you restart, passing...
Pockels Cells Transmission test 19:30: Sweep between 0.1 and 1.5us with 7 steps with Internal Sources. The system configuration is the following: PUPIL Motor ...
Pockels Cells Transmission test Sweep between 0.5 and 2.0us with 4 steps with Internal Sources. Then between 0.1 and 2.0 in 11 steps. The system configuration is ...
Pockels cells installation A try was done to install insulating foam inside the EM shield boxes. Armaflex foam was provided by MPE in several adhesive sheets. Aft...
LgswUnitDx configuration with IS DX LGSW DARK: 20151015_182131 We start redefining the subapertures: we modify the SX ones (20150330_170400). Pup center Subap...
It rained all night, even in the dome. 9:30: telescope back to Zenith we increase the air flow on both units: 4l/min on LGSW and 1.5l/min on PCD 16:00: CalUnit de...
13:30: we try to calibrate the PatCam to Hexapod movement. We do steps pf 5" around the LGSW FoVs. SX LGSW PatCam to Hexapod IM: 20151019_203311 We determine also...
In the morning telescope is dedicate to LUCI1 MOS exchange. 12:15: telescope released, SX and DX CalUnit deployed. LgswUnitSx FoV measurement We do a sweep of /...
SX QC and Pyramid co pointing We switch on the AGW and we configure it to be used with IS. FW1: 600 1000, we center on QC. Board 72.3 50.1 35.0 Then w...
Visual Inspection 11:00: telescope back to Zenith, we climb and check the racks: fine. The pressure gauge on SX PNCCD had low battery. We pumped it anyway up to 0...
LgswUnitSx AO calibration 6:45: start of operations, we try to power up from arbitrator. SX BCU fails to boot twice, then we power cicle from Rack I/O and it work...
LgswUnitDx work LgswUnitDx installation 9:00: we go up to crane back the LGSW: ML leads the operation. 12:00: installation completed, we go back to control r...
LgswSystemSx and LgswSystemDx resume 8:00: startup DX we have several problems: i. error camera: PSU is not communicating, we reboot the Kontron and it is solv...
Log * List of action items for the run: Argos_tasks_20160913.xlsx * List of SW action items for the run: argos_sw_action_items_may2016_lb20160713.xlsx * Sc...
This test was performed by SR after the refurbishment of PockelsCell2, PockelsCell3 and PockelsCell4 (see SR email of 15 Oct 2014): The three DX cells are refurbi...
Daytime * debug of the NaN PBL in the TruthSensing. * Test of the procedure to fit the PSF on PatCams Nighttime DARK LGSW: 20150226_021930 We set the FLAO cub...
Daytime activity DARK LGSW: 20150226_225951 PockelsCellsTransmission test To check the proper behaviour after 10 hours of rest. Scan between 0.1 and 2.0us in 7 s...
20:00: we start to prepare for opening the dome... 21:00: PockelsCellsTransmission on LgswUnitSx: TN Plot Map ('20151023_040836','20151023_040956') ...
Some useful code Old code starting argos_dx_lgsw_terminal from argos.arbitrator.controller_client import FakeAARBControllerClient aarb= FakeAARBControllerClient('...
Description Versions The are several version of this device: * The 2012 model (aka v1.0) that have shown degradation of plastic holders due to ozone pollution...