50 recent changes in ARGOSPublic Web retrieved at 00:38 (GMT)

DayTime20141128
8:30: we start setting up the system for calibrations 9:30: ready to close the loop on ARGOS we acquire a Board setup: 28 Nov 14_argos_calibunit with FLAO BIN4 PB...
DayTime20141127
8:30: start of calibration unit activity, spots are already in LGSW HEXA X Y Z Rx Ry 5.02 7.27 4.38 365 135 We close the loop witho...
DayTime20141126
8:00: we start setting up the system for calibrations. HEX X Y Z Rx Ry 3.02 6.27 4.35 324 155 Acquired new DARK: 20141126_160957 We...
DayTime20141125
8:00: we go up and we switch the fastlink Pathfinder fiber with the ARGOS one. We plug then the TT fiber on the AGW patch panel (the space there is very tight). W...
BrokenTipTiltFiber
First fiber boundle went broken by the crew when routing it to the LGSW rack, so a second one was installed: On 11/20/2014 2:47 PM, Jim Wiese wrote: Gustavo, The ...
DayTime201411202
Pockels cell trasmission test with IS TN* *SUP '20141202_013759', '20141202_014047' '20141202_014849', '20141202_015159'
DayTime20141124
Pockels Cells Transmission test 19:30: Sweep between 0.1 and 1.5us with 7 steps with Internal Sources. The system configuration is the following: PUPIL Motor ...
DayTime20141106
9:24: system fully started, LGSW, ADSEC, FLAO, IRTC are ready. On the FLAO we load the board setup 2014 05 16 ARGOS cal onaxis. Board stage mm X 70 ...
TargetListRun4
Stars * Name* RA DEC Vmag Jmag Hmag Kmag DSS/SDSS Hip117974 23:55:42.83069 31:16:09.2124 10.55 9.184 8.818 8.722 Hip9680...
DayTime20141107
9:30: start of operations FLAO stages @ 72; 49; 37 mm, created Board setup: 07 NoV 14 ARGOS Cal Unit We have a pbl with calibration manager... LB tryes to fi...
DayTime20141104
Calibrations 9:30: start of operations HEXA 2.03 7.25 4.47 31.74 187 0 We have a problem with BCU: when we change subapertures the HVC goes to ...
DayTime20141103
9:00: dichroic CalUnit in M3 758 580 0 25.9 Hexapod coma free movements: X= 0.982mm, Ry= 102" Y= 0.982mm, Rx= 102" Slided Red entrance window by...
DayTime20141102
DX LGSW setup 9:00 a.m.: we start up the LGSW. There is a problem with the state machine: in the powered off state the Thors are off and when you restart, passing...
DayTime20141105
8:00: start of activity, telescope at horizon, WG and DP go up to install the camera to measure the LAS pupil mirror to LM1 coordinates orientation. 11:00: telesc...
HowToStartIRTC
Start up The HW is typically always on. In case you need to access it, the control PC is in the lower treehouse. i. Login as LBTO on obs x . See UsefulLoginInf...
HowToAuthorizeLUCIAtARGOS
How to authorize LUCI@ARGOS focal station 0) login as LBTO on obs x , see UsefulLoginInfo 1) from terminal start TCSGUI 2) click on IIF GUI button 3) on Instrumen...
HowToEnableDayTimeModeInTCS
Rationale When working in day time with the CalUnitSystem the TCS must be informed. If this is not done the TCS offloads the static offsets of the ASM on the prim...
CanDocs
CAN # Description File 002s105b LBT coordinate system 002s105b_ __LBT_AO_Coordinate_System_Definition.pdf 650s003a LUCI focal station distances ...
DiaryRun1
Who When M. Bonaglia 20140309 20140324 L. Busoni 20140309 20140324 T. Mazzoni 20140309 20140324 M. Kulas 20140310 20140324 H. Gemperle...
NightTime20140323
Night Time 20140323 Defined a new target position for PatCams: 20140322_205100 CalUnitSystem light on PatCams in DayTime, TN: 20130322_220800 1:20 Test of Pocke...
NightTime20140423
Night Time 20140323 Defined a new target position for PatCams: 20140322_205100 CalUnitSystem light on PatCams in DayTime, TN: 20130322_220800 1:20 Test of Pocke...
NightTimeActivity
20140320 MATGUI command to start the Mat camera on top of windbracing and check for laser pointing on wide FoV. Username: ???, pwd: ??? 20140322 6:00 II test o...
CalibrationUnitAlignment
Relevant Documents 1 How to deploy ARGOS CalUnitSystem: http://aowiki.arcetri.astro.it/ARGOSPublic/CalUnitTricks 1 Instructions_to_replicate_the_Hexapod_pos...
DayTime20140505
This snapshots were acquired by WG and DP during the CalUnitSystem alignment process. SN tag AO rec LAN focus LM1 phi LM1 piston LM1 theta LAN stat...
DayTime20141030
Servicing of LgswUnitDx Entance windows separation is 137mm (nominal is 137.9mm). This is the same distance that we have in the LgswUnitSx. So the field stop is ...
MpeTest20141015
This test was performed by SR after the refurbishment of PockelsCell2, PockelsCell3 and PockelsCell4 (see SR email of 15 Oct 2014): The three DX cells are refurbi...
PockelsCell1
Known history When Where Who What 20131108 OAA GOX Shipped to Florence from MPE 20131112 OAA MB, LB Installed on LgswUnitSx BlueChanne...
PockelsCell0
Known history When Where Who What 20130808 OAA Arrived in Florence from MPA 20130912 OAA MB, TM Installed in LgswUnitSx in RedChannel ...
DiaryRun0
Who When M. Bonaglia 20140203 20140213 G. Negrini 20140203 20140208 L. Busoni 20140208 20140213 J. Antichi 20140208 20140213 M. Lefeb...
ThingsThatIDontUnderstandTemplate
IMPORTANT NOTE: Do not modify this template topic unless you know what you are doing. If you want to create a new topic using this template use "Create New Topic...
HowToPowerUpLAN
This procedure brings up the LAN system until the launch system is ready for on sky laser propagation i. See FullARGOSStartUpProcedure for prerequisites: chil...
HowToKickOthersOutOfFirefox
The fantastic operating system used for the ARGOS project has the nice feature of allowing only a single instance of the browser to run at any time. i. Kill t...
DayTime20141101
LGSW cabling The sequence of installation was this: 1) PatCams cooling lines, ethernet and power cords 2) Roll bar installation (since the Blue PatCam was reinsta...
DayTime20141031
Dx Lgsw cable tray modification We discovered that the new cable tray installed in September would collide both with the LGSW camera and board so we removed the l...
TipTiltIOSwitch
The TipTiltIOSwitch is a Moxa Nport server that acts as ethernet bridge to the TipTiltComputer and allows power management of the TipTiltComputer. It is part of a...
TipTiltComputer
The TipTiltComputer (also known as Bonn unit) is counting APD electrons and compute the tip tilt signal. It is part of a crate containing also the TipTiltIOSwitch...
TipTiltUnit2
Known history When Where Who What 20130215 OAA JZ, GOX Delivered to Florence with LgswRack1. Never switched on 20131009 OAA MK, GOX, LB ...
DiaryTechRun0
Who When J. Ziegleder S. Rabien W. Raab G. Orban M. Deysenroth H. Gemperlein Installation of Astigmatism Corrector Measur...
NightTime20140518
Log Clouds during first part of the night. TN Notes No TT Res nm wf 20140519_080212 loop instable, REC = 20140519_024141 612 20140519_081237 ...
PockelsCellTest
Some useful code Old code starting argos_dx_lgsw_terminal from argos.arbitrator.controller_client import FakeAARBControllerClient aarb= FakeAARBControllerClient('...
DayTime20140511
Pupil motor X Y Red 465 740 Piezo Rx Ry Red 0.004 0.000 We start recording an IM with 10 modes on the red pupil: IM: 10modes_ol_red....
DayTime20140510
We start recording the IM for the Yellow pupil @ 150Hz. REC: 100modesOK Then we close the loop at 1kHz. TN Notes 20140510_202224 new Snapshot procedure,...
NightTime20140517
22:00 we try to check the LAN optics quality looking at a NGS on a GE1350 camera installed in the LAS box. After focussing we have a 2.5" astigmatic spot when the...
DayTime20140518
subapertures definition: 20140519_014000 extracted from 20140323_055200, centroid normalized on subap flux instead than average subaps flux. subapertures definiti...
DayTime20140517
We center the yellow pupil we close the ARGOS loop on yellow pupil just using 10 modes, with different illuminations: TN Notes Res nm wf No TT Res nm w...
NightTime20140515
We start in the afternoon testing in remote the PC #5 suppression on LgswUnitSx: http://aowiki.arcetri.astro.it/bin/view/ARGOSPublic/PockelsCellTest Cal Unit acti...
NightTime20140516
We start the calibration unit activity putting the on axis source on FLAO. Hexapod Value X 4.3 Y 2.9 We close the loop on FLAO with 400 modes ...
LanLookupTable
LAN flaxures lookup table 2014 05 14 We check the LAN flexures: presetAcquire on target, we collimate (presetAo) and then track. The first pointing is our refer...
NightTime20140514
23:20: we have the spots on the PatrolCameras We try the Patrol to LM1 loop. We load the REC 033220. Then we try the PatCam to periscope loop, when we have a dist...
Number of topics: 50
< Previous Page 11 of 15 Next >

See also: rss-small RSS feed, recent changes with 50, 100, 200, 500, 1000 topics, all changes

This topic: ARGOSPublic > WebHome > WebChanges
Topic revision: 16 Feb 2013, AoAdmin
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding AOWiki? Send feedback